Thunderbolt designs, builds and capacity-tests lithium batteries for inverters and UPS systems in our Dubai workshop: LiFePO₄ battery backup for offices, telecom sites, server rooms and data centres, clinics, shops and homes. We size each battery to your load and the backup time you need, set its BMS to talk to your inverter or UPS, and deliver it ready to connect — or supply the inverter with the battery as one commissioned system — across the UAE, Saudi Arabia, Qatar, Kuwait, Bahrain and Oman.
What our UPS and backup power battery service includes
A UPS or an inverter is only as good as the battery behind it. Most backup systems in the region still run on sealed lead-acid blocks that lose their capacity in the heat long before anyone notices — until the power goes and the backup lasts minutes instead of hours. We replace that with a lithium battery engineered for your system. You get:
- Engineering. Sizing from your load list and the backup time you need, the choice of voltage, cells, BMS and enclosure, and a costed proposal.
- The battery. New grade-A LiFePO₄ cells, matched before assembly, a BMS with temperature sensors and balancing, copper busbars, a DC breaker and a display on the case.
- Inverter and UPS integration. The BMS configured to your inverter's battery protocol over CAN or RS485, so the inverter sees the real state of charge, temperature and limits instead of guessing from voltage.
- An inverter with the battery, if you need one. We can select and supply a hybrid inverter, the breakers and the cabling, and hand over a system that is already set up and tested together.
- A capacity test and its log. Every battery is charged, balanced and discharged in our workshop before it leaves, so you know its real capacity, not just the label.
- Delivery, handover and service. Pickup in Dubai or delivery across the UAE and the GCC under our delivery policy; warranty up to 36 months on components and workmanship, stated in the order.
Who it is for
| Customer | What they need | Typical battery |
|---|---|---|
| Offices and server rooms | Keep servers, network, phones and lighting up through an outage or until the generator takes over | 48–51.2 V, 5–30 kWh |
| Data centres and IT integrators | Lithium battery cabinets for existing UPS systems, with less floor space and weight than lead-acid | 48 V or high voltage, built to the UPS |
| Telecom and network operators | −48 V DC backup for rooftop and remote sites that run unattended in heat | 48 V, 2–15 kWh |
| Clinics, labs, shops and restaurants | No lost fridges, records or tills when the power drops | 24–48 V, 3–20 kWh |
| Villas and apartments | An inverter with battery for Wi-Fi, lights, fridges, CCTV and a few sockets | 24–48 V, 2.5–15 kWh |
| Factories and remote sites | Three-phase backup or off-grid power with a generator as the charger | 48 V banks in parallel, 20–100+ kWh |
Why switch your UPS or inverter to lithium
- Heat kills lead-acid batteries. Sealed lead-acid life halves with every 8 °C of extra temperature; a battery rated for 10 years at 25 °C lasts about five years at 33 °C, according to Battery University. A UPS cupboard in a Gulf summer is often hotter than that.
- More usable energy from the same space. LiFePO₄ can give 80–90% of its capacity on every discharge; lead-acid lasts longest at about half.
- You can see the battery. A lead-acid string gives the inverter a plus and a minus. Our BMS reports every cell's voltage, the temperature and any fault to the inverter and to the screen on the case.
- Fast recharge. After an outage a lithium battery is ready again in hours with a charger sized for it, so a second cut the same day does not find it half empty.
- No routine maintenance, no gassing. Nothing to top up, and no hydrogen venting on charge in an office or a server room.
How it works: from brief to a working backup system
- Brief. You send the inverter or UPS model, the loads to keep running, the backup time and a photo of where the battery will stand — by WhatsApp or the quote form.
- Engineering and proposal. The battery configuration, the cells and their datasheet, the protocol settings, the warranty, the price and the date.
- Assembly. Cell matching, assembly and BMS programming for your inverter, in our Dubai workshop.
- Capacity test. Each battery is charged, balanced and discharged; you receive the measured capacity. If we supply the inverter, we start the system and set it up before it leaves.
- Delivery or pickup. Builds start from two working days; larger systems take longer and the date is in the quote.
- Support. Questions are answered from the BMS data; expansion, service and capacity tests when needed.
Why Thunderbolt
- Built here, not imported. We assemble and test in Dubai, so the battery is made for your inverter and your room, and we can service it locally.
- Any voltage, any cabinet. 12, 24 and 48 V batteries, high-voltage strings for larger UPS units, wall-mounted and rack-mounted cases, narrow cabinets for a cupboard.
- We build whole systems. Our 20 kW three-phase UPS runs on twelve of our batteries — see the project.
- Proof before delivery. A measured capacity for every battery, not a datasheet promise.
Inverter battery and UPS battery types we build
Every battery starts from your inverter or UPS, your loads and the time you need to bridge. Typical builds:
| Battery | Voltage | Capacity | Typical use |
|---|---|---|---|
| Home inverter battery | 24–51.2 V | 2.5–7.2 kWh | Apartment or villa essentials with a 3–6 kW inverter |
| Wall-mounted 48 V battery | 51.2 V | 5.4 kWh per unit, in parallel | Hybrid inverters, offices, villas |
| Rack bank for a UPS | 48 V or high voltage | 10–65+ kWh | Server rooms, clinics, production lines |
| Telecom battery | 48 V (−48 V DC) | 2–15 kWh | Rooftop and remote telecom and network sites |
| Portable UPS | 12–24 V with an inverter | 1–3.6 kWh | Events, site offices, small homes without fixed wiring |
These are the ranges we quote most often, not limits. A battery for an unusual UPS voltage or a cabinet of a fixed size is exactly what a custom build is for.
Inverter with battery or battery only: which do you need?
Many people search for an "inverter with battery" because they want one working package. That is often the simplest choice, but not always the right one:
- You already have a UPS or inverter. We build a lithium battery to its voltage, current and protocol. For an online UPS that expects lead-acid, we check its charger settings first and set the BMS to stay inside them.
- You are starting from zero. We supply a hybrid inverter and the battery as one system, set up and tested together, with the breaker and cables cut to size. A hybrid inverter also accepts solar panels and a generator later.
- You are not sure how big it should be. Start with the inverter and one battery, measure how long your real loads run, then add identical batteries. Our 48 V batteries join in parallel, so a bank can grow without replacing anything.
LiFePO₄ vs lead-acid for UPS battery backup
Lithium iron phosphate is the chemistry we use for backup. Battery University lists it at 2,000 cycles and more, with good thermal stability and tolerance to abuse. For backup that cycles several times a day, or where the battery must recharge very fast, we also build LTO (lithium titanate) batteries.
| Chemistry | Usable depth of discharge | Typical cycle life | In Gulf heat | Where it fits |
|---|---|---|---|---|
| Sealed lead-acid (VRLA, AGM) | about 50% | hundreds | life halves with every 8 °C above 25 °C | cheap standby that rarely cycles, in a cooled room |
| LiFePO₄ | 80–90% | 2,000–6,000+ | good — more stable than NMC | offices, telecom, homes, frequent outages |
| LTO | 90%+ | 10,000+ | very good | several cycles a day, very fast recharge |
Cycle life depends on temperature, depth of discharge and charge rate, so these are typical ranges, not a promise for a specific battery. For your build we state the cells, their datasheet and the warranty in the quote.
UPS batteries for Gulf heat, dust and humidity
- Placement first. An air-conditioned room or a shaded, ventilated cupboard adds more years than any part we can fit. We ask for photos of the location before we quote.
- BMS temperature limits. Four temperature sensors along the cells; the BMS reduces or stops charging before the cells are at risk and stops discharging if they overheat.
- Dust and coastal air. Sealed cases, insulated terminals and coated busbars for rooftop telecom cabinets and coastal buildings.
- A case that can be opened. Our lids are bolted to brass threaded inserts, not glued, so a battery can be serviced cell by cell.
Inside a lithium inverter battery
- Cells. New grade-A prismatic LiFePO₄ cells, from EVE and other established makers, checked for voltage and internal resistance and matched before assembly. The cells sit in rigid holders that keep them under compression, which extends their life.
- BMS. Protection for every cell against over- and under-voltage, over-current and temperature, with balancing built in, or a separate active balancer of up to 5 A on larger batteries.
- Display. A screen on the case shows the state of charge, cell voltages and errors without a phone; in a bank, one master battery shows and reports the whole bank.
- Busbars, breaker and wiring. Copper sized for the continuous and peak current, torque-checked joints, a DC breaker as the isolation point for the installer.
Inverter and UPS battery compatibility: CAN, RS485 and lead-acid mode
A lithium battery works best when its BMS talks to the inverter. Before we quote we check the inverter model and its battery protocol, usually over CAN or RS485, and configure the BMS for closed-loop communication — we have built batteries for Deye and for Growatt's low-voltage protocol, among others. The inverter then charges by the battery's real state, limits the current to what the BMS allows, and shows an error instead of running on as if nothing happened.
If your UPS has no battery communication, the battery runs in voltage mode: we match the BMS limits to the UPS charger's float and cut-off voltages, so the BMS protects the cells and the UPS still sees a battery it understands. For telecom, the ETSI standard for −48 V equipment sets a normal service range of −40.5 V to −57.0 V at the equipment input (ETSI EN 300 132-2); a 16-cell LiFePO₄ battery at 51.2 V nominal sits inside it when its charge voltage is set at or below 57 V rather than the full 58.4 V.
How to size a UPS battery backup: a worked example
An office wants its server rack, network switches, Wi-Fi, phones and emergency lighting to run for two hours through an outage: about 1.5 kW on average.
÷ 0.9 for inverter losses (an assumption; check your inverter's datasheet) ≈ 3.3 kWh from the battery
÷ 0.9 usable depth of discharge ≈ 3.7 kWh installed
51.2 V × 105 Ah = 5.4 kWh → one battery, with a margin for ageing
Two more checks follow. Power: the inverter and the battery must deliver the peak, so we check the BMS current limit against the inverter rating and the start-up current of anything with a motor. Recharge: the battery has to refill before the next outage, so the inverter's charge current and the BMS charge limit must match. The same arithmetic, with your real load list, is the first thing we do on every project.
Inverter battery price in the UAE: what drives the cost
- Usable kilowatt-hours. Cost scales with capacity; the backup time you ask for decides it.
- Voltage and BMS. High-voltage strings for large UPS units need contactors, pre-charge and a more capable BMS; a 48 V battery is simpler.
- Battery only, or a system. An inverter, breakers, cabling and commissioning add to the price, and save you matching parts from different suppliers.
- Enclosure. A rack module for a cooled room costs less than a sealed rooftop cabinet.
- Lifetime cost. A LiFePO₄ battery costs more to buy than lead-acid, but in a hot room the lead-acid battery is replaced several times over the same years.
Send us the brief and we return a costed proposal — request a quote.
Battery backup across the UAE, Saudi Arabia, Qatar, Kuwait, Bahrain and Oman
We build in Dubai and deliver to all seven Emirates — Dubai, Abu Dhabi, Sharjah and the northern Emirates — and to Saudi Arabia, Qatar, Kuwait, Bahrain and Oman (see our delivery policy). Large UPS banks go by truck and can be installed and commissioned on site. What changes from place to place is the site, not the battery: rooftop telecom cabinets in the summer sun, server rooms in older buildings with weak cooling, coastal offices with humid, salty air, and farms and sites outside the cities where backup becomes off-grid power with a generator. For backup that also stores solar, see our page on solar battery storage in the UAE & GCC.
Safety, standards and paperwork
Every battery leaves the workshop after a full capacity test, numbered for commissioning and remote support, and shipped at about 30% charge. The cells we use have passed the UN 38.3 transport tests; the finished battery is shipped as Class 9 dangerous goods under the rules that apply to its size and production run. The reference we design stationary and UPS batteries to is IEC 62619, the safety standard for lithium cells and batteries in industrial uses including telecom and UPS; the UPS unit itself is covered by IEC 62040-1. Your electrician follows the local wiring and civil-defence rules for the room. If your project needs specific certificates for a tender or an inspection, tell us at the brief stage.
Related applications
The same batteries run in our other builds: solar battery storage for villas and farms, 12 V and 24 V LiFePO₄ batteries for CCTV, alarms and industrial controls, portable power stations, and off-grid power for caravans and motorhomes. Old packs can be rebuilt through our battery repair and replacement service.
From our work
- 20 kW three-phase UPS for a production site with no grid: twelve of our 48 V 105 Ah LiFePO₄ batteries in parallel — 1,260 Ah, about 64.5 kWh — with a Deye 20 kW hybrid inverter and a 30 kW gas generator as the charger. Charge and discharge are limited to 300 A (about 15 kW from the battery; the generator covers the rest), below the inverter's 350 A. Each battery measured 110 Ah on test, 5% above its rating. We supplied it turnkey and commissioned it on site — read the full project.
- 5 kW home and office UPS: a 48 V 105 Ah LiFePO₄ inverter battery (5,040 Wh on the label, 5.4 kWh at 51.2 V) with a 6.2 kW hybrid inverter, a two-pole breaker and power cables crimped to size. The battery reports its temperature, power, charge and errors to the inverter by cable. Runtime at the battery's rated energy, before inverter losses and depth of discharge: 5 kW for up to 1 hour, 2.5 kW for up to 2 hours, 1.5 kW for about 3 hours.
- 2.5 kW home backup sets: a 3.6 kW hybrid inverter with one 2.5 kWh LiFePO₄ battery — at rated energy, before losses, 2.5 kW for up to 1 hour or 1 kW for up to 2.5 hours — expandable to 16 batteries, about 40 kWh, in one power and data chain. One such set keeps a house's CCTV and small appliances running, with the battery reporting to the inverter over RS485. We start each system and enter the settings before it leaves, so it arrives ready to install.
- Long runtime at low power: a 24 V LiFePO₄ battery of 7.2 kWh with a 3 kW hybrid inverter — at rated energy, before losses, 0.6 kW for up to 12 hours or 1.5 kW for up to 4.8 hours.
- Start with one battery, grow later: an 11 kW hybrid inverter with one 5.4 kWh battery, so the owner could measure the real runtime of his loads before adding identical batteries.
- Wall-mounted 51.2 V battery for a Growatt inverter: 5.4 kWh in one block, cells under compression, a BMS on the Growatt low-voltage protocol and a display on the front.
- Portable UPS: a 12 V battery and a 1.2 kW inverter with automatic switchover and a built-in charger, on an aluminium frame — at rated energy, before losses, 1.2 kW for up to 1 hour or 0.2 kW for up to 6 hours.
What to send us for a quote
- The UPS or inverter model, or the power you need if you have none yet.
- The loads to keep running and for how long — a list with watts, or the UPS load reading.
- Where the battery will stand, with a photo, and the country and city of the site.
- Whether there is a generator or solar, and whether the system is single- or three-phase.
Send it by WhatsApp or through the quote form — we reply on WhatsApp during working hours with questions or a costed proposal.
Frequently asked questions
How long will an inverter battery last during a power cut?
Divide the battery's usable energy by the load. A 48 V 105 Ah LiFePO₄ battery stores about 5.4 kWh; after inverter losses and depth of discharge it runs a 1.5 kW load for about three hours, or a 500 W load for about nine.
Which battery is best for an inverter in the UAE heat?
LiFePO₄. Sealed lead-acid life halves with every 8 °C above 25 °C, while LiFePO₄ is the most thermally stable common lithium chemistry and lasts thousands of cycles. It still ages faster when hot, so place it in a cool, ventilated spot.
Can I replace the lead-acid batteries in my existing UPS with lithium?
Usually yes. We check the UPS voltage, charger settings and battery protocol, then build a LiFePO₄ battery whose BMS works inside those limits — with communication where the UPS supports it, in voltage mode where it does not.
Do you sell an inverter with battery as one package?
Yes. We can supply a hybrid inverter, the battery, the breaker and the cabling as one system, set up and tested together before delivery. A hybrid inverter also accepts solar panels and a generator later.
What size UPS battery do I need for an office or server room?
Add up the watts of the equipment you must keep on, multiply by the hours of backup, then allow about 10% for inverter losses and 10% for depth of discharge. Send us the list and we do the calculation for you.
Do you build 48 V batteries for telecom sites?
Yes. A 16-cell LiFePO₄ battery at 51.2 V nominal fits the −48 V DC range telecom equipment uses when its charge voltage is held at or below 57 V, with sealed cases and BMS temperature limits for rooftop and remote cabinets.
Can I add more batteries later?
Yes. Our 48 V batteries connect in parallel and link to one master battery that reports the bank to the inverter. Adding batteries of the same type within the first year or two works best.
How much does an inverter battery cost in the UAE?
It depends mostly on usable capacity, the voltage, whether you need an inverter too, and the enclosure. LiFePO₄ costs more to buy than lead-acid but usually less over its life. Send us your brief and Thunderbolt returns a costed proposal.
Do you deliver UPS batteries outside Dubai?
Yes — to all seven Emirates and to Saudi Arabia, Qatar, Kuwait, Bahrain and Oman, as Class 9 dangerous goods. Large systems go by truck and can be commissioned on site; the method and date are in the quote.
Sources
- Battery University — BU-806a: How Heat and Loading affect Battery Life — sealed lead-acid life halves with every 8 °C rise; 10 years at 25 °C becomes 5 years at 33 °C
- Battery University — BU-205: Types of Lithium-ion — LiFePO₄ cycle life of 2,000 and higher, thermal stability
- ETSI EN 300 132-2 V2.6.1 (2019-04) — power supply interface for ICT equipment at −48 V DC; normal service range −40.5 V to −57.0 V
- IEC 62619 — safety requirements for lithium cells and batteries in industrial uses, including telecom, UPS and energy storage
- IEC 62040-1 — uninterruptible power systems (UPS), part 1: safety requirements
- Intertek — UN 38.3 testing — nearly all lithium batteries must pass section 38.3 of the UN Manual of Tests and Criteria for transport